May 17, 2024

Pump factory performance test and running test

Each pump at the factory should be at the design speed of the performance test and run the test. So how to pump test it?

Pump performance test should be carried out at five different flow rates (including shut-off point, the minimum continuous flow and design capacity of 110% in order to get a reasonable performance curve

Pump mechanical operation test: After the performance test, mechanical continuous operation test should be conducted under design conditions to check the mechanical operation. The inspection time is usually one hour. When the test equipment can not be operated at the design speed, the test speed can be Different from the design speed, the range of the rated speed of the demolition as necessary if necessary, the initial test results invalid, the final test shall prevail.

Pump performance curves and data include: total head, efficiency, shaft power and speed and correction calculations made to HQ, PQ, curve vibration and temperature rise; noise measurement; NPSH test;

Note: The above content from the network.

This article Keywords: water pump

Round Open Water Cooling Tower

The whole structure is solid and light;the body and water pond is manufactured with reinforced glass fibre (FRP glass fiber reinforced plastics),never being corrosive. The surface finish is added with ultraviolet inhibitor,which can resist sunshine attack and damage.

All steel and iron material is processed through galvanizing by dipping,Ocorrosion resisting and durable.

Special designed axial-flow type air blower applies belt reduction gear,reducing low noise and sufficient wind; tailor-made water-drop noise
reduction carpet to eliminate water sound.

Apply special design PVC water block curtain (water-stop) to prevents plashing) remarkably; pressure drop loss is slight and splashing loss i under 0.001%.

Special designed water sprinkler with big bore diameter,which won' t cause blocking but the sprinkling effect is very good. It is installed in the tower,so it won' t bee polluted by outside dust and foreign matters.


Apply cellular vacuum molding heat dissipation material, stagger arrangement surface has grooves and the heat exchange effect is especially good.


Water pond applies slant design, easy to wash, containing less water; the operating weight is lower, but the water tank is very big, so it won't absorb air.

The cooling tower support is light and solid, convenient to assembly no matter there is suspension iron rack or not.


Round Open Water Cooling Tower,Water Cooling Tower,Round Cooling Tower,Cool Water Towers

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhou-arkfluid.com